Description: Model 1:TLC9803(5007) 3-channel 24h holter ECG+PC softwareIntroduction Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.Function 1)The recorder can real-time store ECG data for 24-hour. 2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work. 3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms. 4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel. 5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis. 6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc. 8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function. 9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability. 10)One-key print, convenient and fast to print the reports. 11)Perfect case management function. 12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function. 13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function. 14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac deathPerformance Lead: 3-lead Record time: 24-hour Power supply: two “AA” batteries Interface: USB2.0 Calibration voltage: 1mV±5% Noise level: ≤30μV CMRR: ≥60dB Low-frequency characteristics: time constant≥3.2s Scan speed: 25mm/s±5% Polarizing voltage: ±300mV, sensitivity: ≤±10% Minimum measure signal: 50 µV p-pAccessories Lead cable (1 set) ECG electrode (1 bag) USB cable(1) Bag(1) User manual(1)Physical characteristic Dimension: 111mm(L) × 60mm(W) × 25mm(H) Weight: about 105g(without batteries) Model 2:TLC5000 12-channel 24h holter ECG+PC softwareIntroductionTLC5000 Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.Function1)The recorder can real-time store ECG data for 24-hour. 2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work. 3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion. 4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms. 5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel. 6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis. 7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc. 9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function. 10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability. 11)One-key print, convenient and fast to print the reports. 12)Perfect case management function. 13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia. 14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function. 15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function. 16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death. 17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.PerformanceLead: standard 12-lead Record time: 24-hour Power supply: two “AA” batteries Interface: USB2.0 Calibration voltage: 1mV±5% Noise level: ≤30μV CMRR: ≥60dB Low-frequency characteristics: time constant≥3.2s Scan speed: 25mm/s±5% Polarizing voltage: ±300mV, sensitivity: ≤±10% Minimum measure signal: 50 µV p-pAccessoriesLead cable (1 set) ECG electrode (1 bag) USB cable(1) Bag(1) User manual(1)Physical characteristicDimension: 111mm(L) × 60mm(W) × 25mm(H) Weight: about 105g(without batteries) Model 3:TLC6000 48h 12-channel holter ECG+PC SoftwareBrief IntroductionTLC6000 Dynamic ECG Systems contains recorder & analysis software. Recorder is an easy- to -use unit, which collects 12-lead ECG waveform synchronously and records continuously for 48 hours. Recorder featuresCompact design.OLED display.Function of event marking.Removable TF card(volume: up to 2GB).One "AAA" size battery can collect the ECG data of 48-hour.Ten electrodes synchronously collect the 12-lead ECG data. The features of softwareWith 12 leads synchro analysis , QRS search can be more exactlyThere are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc.and multiplicate User-defined templates could almost identify every kind of pathologic waveformsFlexible atrial fibrillation analysis, so that physicians can use full, segmented automatic, manual analysis of atrial fibrillation, make the analysis more quickly and accuratelyPowerful pacemaker analysis, on the AAI, VVI, DDD etc. all pacemaker analysisAny period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysisAnalysis of heart rate variability with short-range 5 minutes and long-range 1 hour and full analysis of heart rate variabilityA one-stop printing operation, report printing process is convenient and quick"Heart rate turbulence" analysis can predict the risk of death in patients with myocardial infarction"T Wave alternation" analysis is a important index on judging and preventing ArrhythmiaThe report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis. StandardLead mode: standard 12-leadSampling accuracy: 12bitRecording time: 48hScale voltage: 1mV±5%Standard Sensitivity: 10mm/mV±5%Noise level: ≤30μVCMRR: ≥60dBLow-frequency characteristics: Time constant≥3.2sEnduring polarization voltage:±300mV DC polarization voltage,sensitivity shift≤±10%Least measure signal: 50 µV p-pProduct safety type: Type B applied part(Internally powered equipment) Accessories:ECG lead wires(12-Lead)ECG electrode(20 per bag)Host bag(1)User manual(1) Physical CharacteristicDimension: 80.5mm(L) *59.5mm(W) *22mm (H)Weight: 61.5g Payment 1.Paypal2.Bank transferShipping1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.2. Your item will be sent via Air mail within 48 hours after payment is received. The shipping time is around 2-6 weeks.US buyer 2-5 days delivery. 3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extra charges from the import countries.4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase. International Buyers - Please Note:* Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.* Please check with your country's customs office to determine what these additional cost will be prior to bidding/buying.Terms of SaleBuy Safe Product!The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K ApprovedFeedbackPlease leave me a positive feedback if you are satisfied with our products, Your positive feedback will be appreciated,thank you.If you have any problems, please contact us asap before you open a case and leave a negative feedback or ship the item back, we promise we will give you a satisfied answer, thank you for your understanding! Return - After serviceWe offer 60 days return policy. 100% satisfaction is our goal!1.All items are brand new ,with 1 years warranty. 2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item. 3.We will refund the money to you when we get the return items or replace item for you.4. All return items must be returned with its original package and accessories.About usContec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.Contact usVivian Zhang Only English User Manual,Please contact us if you need other language manual.
Price: 299 USD
Location: Elk Grove Village, Illinois
End Time: 2023-12-21T13:33:29.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Number of Channels: 3/12 channel
ECG & EKG Machine Type: Holter Monitor
Number of Leads: 12 lead
Country/Region of Manufacture: United States
MPN: 69450401
Brand: CONTEC
Available Variations
Color: tlc9803(5007) 3-channel 24h
Price: 299 USD
Available Quantity: 101
Quantity Sold: 1
Color: tlc5000 12-channel 24h
Price: 499 USD
Available Quantity: 100
Quantity Sold: 0
Color: tlc6000 48h 12-channel
Price: 499 USD
Available Quantity: 105
Quantity Sold: 5