Description: Refrigerated Freeze Dryer 70 CFM 15C Refrigerating Dryer Air Compressor 220V 800W Flow capacity:70 cfm Refrigerant Type:R134A Voltage:220V Power:800W Interface pipe diameter: ZG1.0 Air capacity: 2.5m³/min Work pressure: ≤1.0Mpa Inlet temperature: ≤80℃ Dew point temperature: 2-10℃ Working principle: The humid and high temperature compressed air flows into the front cooler after the heat exchange into the heat exchanger and the cold air discharged from the evaporator, so that the temperature of the compressed air into the evaporator is reduced. The air of the heat transfer into the evaporator through the evaporator heat transfer function and refrigerant heat exchange, the heat in the compressed air is taken away by the refrigerant, compressed air rapid cooling, the wet air moisture reaches saturation temperature rapid condensation, condensed water after condensation, after the unique air water separator high speed rotation, water due to the action of the centrifugal force and air separation, after separation of water from the automatic drainage valve. The lowest air pressure dew point after cooling can be up to 2℃ after cooling. After cooling the cold air flows through the air heat exchange and inlet of hot humid hot air heat exchange, the heat exchange of cold air for absorb the heat, the inlet air and the compressed air through the freezing system of secondary condenser and high temperature refrigerant heat exchange again make the outlet temperature is fully heated, to ensure that the outlet air pipeline is not exposed. At the same time, it makes full use of the outlet air cooling source to ensure the condensation effect of the freezing system and ensure the quality of the outlet air of the machine. Operation method: 1. Check whether the refrigeration system pressure of the machine is normal. Check that the ball valve at the front of the automatic drainage valve is open. 2. Send the power supply to the control box, press ON/OFF button switch ON button, machine contactor suction, compressor operation. At this time, the refrigerant low pressure gauge pointer should indicate that it is in the range of 60~85Psig. If the load exceeds this range, adjust it. 3. After the compressor runs smoothly, the pressure of the refrigerant high pressure gauge rises to between 120 and 240psi. When the high pressure of the refrigerant is higher than this range, check whether the heat dissipation of the condenser is good, and whether the inlet temperature of the air compressor and the ambient temperature are too high. When the antifreeze switch is lower than 140Psig, the condensing fan stops running to increase the pressure to ensure the normal operation of the machine. If the machine is operated at low pressure for a long time, check whether the refrigeration system leaks. 4. Please turn off the air compressor before shutting down. After turning OFF the air compressor, press the ON/OFF switch to turn off the power supply of the machine. Note: 1. Please turn on the cold dryer for about 5 minutes before using the gas. 2. It is recommended that the side of the power cable connected to the machine should be against the wall, with the front side at least 1 meter away from the wall and the back side at least 20 cm away from the wall. 3. The drain time can be adjusted. If it needs to be adjusted longer, the SEC key on the left can be adjusted to 2 seconds, and the MIN key on the right can be adjusted to 5 minutes (0-10 middle). 4. Be sure to wrap raw material tape or use liquid sealant when installing. On Jan 17, 2024 at 21:23:18 PST, seller added the following information:
Price: 1155.26 USD
Location: Rancho Cucamonga, California
End Time: 2024-10-18T13:00:01.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: TECHTONGDA
Airflow Volume: 70 CFM
Maximum Compressor Horsepower: 15 hp
MPN: 239848
Compressed Air Dryer Type: Refrigerated Dryer