Description: Model: RPM-9000C2 Portable Dental Oral implant?Patient Monitor is adaptable to adult, pediatric and neonatal usage.It?can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant. Features: 10 inch color high resolution TFT display. Can be arbitrarily set the alarm limit, automatic sound and light alarm Anti-movement, anti-defibrillation, anti electrosurgical interference Remote central monitoring network interface Drug solubility calculation function, Arrhythmia analysis function Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.?? Standard configuration: ECG, NIBP, SPO2, TEMP, RESP,PR Specification: ECG Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V) Lead selection:I, II, III, avR, avL, avF, V, Waveform:2 ch Lead mode:3 Leads ( R, L, F or RA, LA, LL) Lead selection:I, II, III, Waveform:1 ch Gain:′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto HR and Alarm? Range:? Adult:15 ~ 300 bpm Neo/Ped:15 ~ 350 bpm Accuracy:± 1% or ± 1bpm,which great Resolution:1 bpm Sensitivity:> 200 (uV P-P) Differential Input Impedance:> 5 MΩ RESPARATION: Method:Impedance between R-F(RA-LL) Differential Input Impedance:>2.5 MΩ Measuring Impedance Range:0.3~5.0Ω Base line Impedance Range:0 – 2.5 ?KΩ Bandwidth:0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range? Adult:0 ~ 120 rpm Neo/Ped:0 ~ 150 rpm Resolution:1 rpm Accuracy:±2 rpm Apean Alarm:10 ~ 40 S NIBP Method:Oscillometric Mode:Manual, Auto, STAT Measuring Interval in AUTO Mode ?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode:5 Min Pulse Rate Range:40 ~ 240 bpm Alarm Type:SYS, DIA, MEAN Measuring and alarm range:??? Adult Mode SYS :40 ~ 270 mmHg DIA :10 ~ 215 mmHg MEAN:20 ~ 235 mmHg Pediatric Mode SYS:40 ~ 200 mmHg DIA:10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS:40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Overpressure Protection Adult Mode:297±3 mmHg Pediatric Mode:240±3 mmHg Neonatal Mode:147±3 mmHg SpO2 Measuring Range:0 ~ 100 % Alarm Range:0 ~ 100 % Resolution:1 % Accuracy:????? 70% ~ 100% ?±2 % 0% ?~ ?69% ?unspecified Actualization interval:about 1 Sec. Alarm Delay:10 Sec. Pulse Rate Measuring and Alarm Range:0~254bpm Resolution:1bpm Accuracy:±2bpm I.5TEMP measurement: Channel:1 Measuring and Alarm Range:0 ~ 50 °C Resolution:0.1°C Accuracy:±0.1°C Actualization interval:about 1 Sec. Average Time Constant:< 10 Sec. Package List: 1×Dental Patient Monitor 1×EKG Lead wire 1×NIBP Cuff 1×NIBP Extension Cable 1×SpO2 Sensor 1×Temp Sensor 3×Limp Clip 5×Electrode 1×User ManualOriginally purchased new for medical office. Opened but never used. All in excellent working condition
Price: 399.99 USD
Location: Boca Raton, Florida
End Time: 2024-09-20T19:26:34.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Brand: Unbranded
Technology: Digital
Model: PM12D
Features: portable
MPN: Does Not Apply
Country/Region of Manufacture: China
Unit Quantity: 4
Monitor Parameters: Monitor Parameters
Intended Use/Discipline: Emergency Medicine