Description: CMS6000C Patient Monitor Introduction The monitor has abundant monitoring functions and is used for monitoring of adult, pediatric and neonate. User may select different parameter configurations according to different requirements. It displays real-time data and waveform by 8'' TFT color LCD, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. 48mm thermal printer is optional. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system. This device can monitor such parameters as ECG, SpO2, PR, NIBP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving. Functions Standard parameters: ECG, RESP, SpO2, PR, 1) ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2) RESP Respiration rate(RR) Respiration waveform 3) SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4) NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5) TEMP T1, T2, TDIt has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features 1)8'' TFT color LCD, multi-language interface. 2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3)All-round monitor for adult, pediatric and neonate. 4)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe. 5)Waveform, parameter color and location can be set optionally. 6)Operation mode: keys and buttons. 7)Display up to 8-channel waveform on one screen. 8)Display 7-lead ECG waveform on one screen, and with ECG step function. 9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 10)HRV analysis function. 11)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 12)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 13)Drug concentration calculation and titration table functions. 14)Print trend table data with one-key. 15)Connect to Central Monitoring System by 3G, WiFi or wired mode. 16)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 17)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary). Performance ▲ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-channel 3-lead, 1-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350bpm Accuracy: ±1% or ±1bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy: -0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes RESPIRATION Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s ▲NIBP Method: Oscillometry Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg ▲SpO2 Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified PR Measurement and alarm range: 30 ~ 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater Accessories Adult fingertip SpO2 probe (5-pin) Adult NIBP cuff NIBP extension tube ECG lead cable ECG electrode Power adapter Power cord User Manual Physical characteristic Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H) Weight: 2.5 Kg Buy Safe Product The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
Price: 459 USD
Location: Beijing
End Time: 2024-01-16T04:44:55.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Number of Channels: 8 channel
Screen Dimensions: 8'' TFT color LCD
Model: CMS6000C
Country/Region of Manufacture: China
Features: Multi-language interface, Fanless design, For adult, pediatric and neonate, big character interface, Waveform, parameter color and location can be set, Operation mode: keys and buttons., Display up to 8-channel waveform on one screen., HRV analysis function, titration table functions, Print trend table data with one-key., Battery Operated, Handheld, USB Connection
Technology: Digital
MPN: Does Not Apply
Monitor Parameters: PR, Blood Pressure, Blood Pressure - NIBP, Blood Pressure - IBP, Blood Pressure - Systolic Pressure, ECG, O2 - SpO2, Respiratory Rate
Brand: CONTEC
Intended Use/Discipline: Emergency Medicine