Description: We ship world wide - please contact us for more specific shipping options.Druck DPI620 - multifunctional calibrator Measure, source and simulate multiple parameters HART Communicator Full Capabilities of a Stand Alone Communicator Free Upgrades via the Internet – Upgrade your DD Library, No Special Software Required, No Additional Cost Powerful Device Configuration, Commissioning and Maintenance Capabilities Complete Library of all Registered HART® Device Descriptions Easy-to-use, with video quality touch screen, which can be operated by a gloved hand Weather-proof to IP 65 Can display up to 6 active readings Available with a range of add-on modules, pressure measurement modules and generation stations, Intecal Field Calibration documenting module, 300Vac measurement probe Digital interface for pressure modules and future options USB master and slave for connecting to a PC and peripherals Long-life Lithium-Polymer battery pack COMPACT AND POWERFUL The DPI 620 electrical calibrator can measure and source mA, mV, V, Ohms, frequency and a variety of RTDs and T/Cs. It provides an isolated 24 V loop power supply to energise devices and control loops and a stabilized dc voltage supply for ratio metric transducers. The high resolution, color touch screen of the calibrator shows only those buttons necessary for the immediate, selected tasks. The buttons have been sized so that they can be operated by a gloved hand, with no need for a stylus. The display can be configured to show up to six reading windows and can show electrical and temperature inputs and outputs, two pressure module readings, an IDOS pressure measurement, and a USB-connected device, as well as a HART summary window or full HART communicator with active mA measurement and actual primary variable readings. FLEXIBLE AND MODULAR SYSTEM Its basic component is an ultra-compact, electrical, frequency and temperature calibrator and HART communicator, which provides simultaneous measurement and source capabilities with a fully featured HART digital interface. Pressure measurement is provided by interchangeable pressure modules that can be attached to the calibrator by a pressure module carrier. If pressure generation is required the calibrator and pressure module can be attached to one of three pressure generation stations, to form a fully-integrated pressure calibrator, of unparalleled performance. The simple yet sophisticated design and concept combines, for the first time, an advanced electrical calibrator with state-of-the-art pressure measurement and generation, so that there is no longer any need to compromise one measurand capability in favour of another. HIGH-PERFORMANCE HART COMMUNICATOR The DPI 620 multifunction calibrator now incorporates a fully featured HART® communicator which surpasses market leading communicators in functionality, ease of use and upgrade support such that a single hand held device can now configure the full range of HART devices and perform mA trims and sensor calibrations without the need for secondary equipment such as ammeters, calibrators, power supplies and loop resistors. This can significantly reduce equipment inventory, cost of ownership and greatly simplify maintenance activities The DPI 620 contains the latest application software and a complete library of registered HART device descriptions. Upgrades can be simply downloaded free of charge from our website. Electrical Measurement and Source NLH&R ±1°C (2°F) for 24 hrs (note 1) Total Uncertainty 10° to 30°C (50° to 86°F) for 1 year (note 3) Additional error -10° to 10°C (14° to 50°F) 30° to 50°C (86° to 122°F) Resolution Display reading window %Rdg + %FS %Rdg + %FS %Rdg/°C + %FS/°C Measure mode DC Voltage Thermocouple Please refer to Thermocouple specification table CH1 TC mode -10 to 100 mV 0.0045 0.008 0.007/0.009** 0.01 0 0.0005 0.001 CH1 ± 200 mV 0.0045 0.004 0.007/0.0085** 0.005 0 0.0005 0.001 CH1 CH2 ± 2000 mV 0.004 0.003 0.007/0.008** 0.005 0 0.0005 0.01 CH1 CH2 ± 20 V 0.0025/0.0035** 0.002/0.0025** 0.01/0.018** 0.002/0.0025** 0 0.0005 0.00001 CH1 CH2 ± 30 V 0.0035/0.005** 0.0035/0.0045** 0.01/0.019** 0.004/0.0045** 0 0.0005 0.0001 CH1 CH2 AC Voltage1* 0 to 2000 mVAC 0.125 0.125 0.2 0.15 0.005 0.005 0.1 CH1 0 to 20 VAC 0.1255 0.125 0.2 0.15 0.005 0.005 0.001 CH1 0 to 300 VAC 1 0.06 1.5 0.1 0.05 0.005 0.01 CH1 Current ± 20 mA 0.006 0.005 0.012/0.016** 0.006/0.0065** 0 0.0005 0.0001 CH1 CH2 ± 55 mA 0.005 0.005 0.016/0.019** 0.005/0.0055** 0 0.0005 0.0001 CH1 CH2 Resistance (True, 4 wire) RTD Please refer to RTD specification table CH1 0 to 400 Ω 0.0055 0.001 0.009 0.0012 0 0.0005 0.001 CH1 0 to 4000 Ω 0.0055 0.001 0.009 0.0012 0 0.0005 0.01 CH1 Resistance (4 wire) RTD Please refer to RTD specification table CH1 0 to 400 Ω 0.012 0.005 0.015 0.006 0 0.001 0.001 CH1 0 to 4000 Ω 0.0115 0.0045 0.015 0.006 0 0.001 0.01 CH1 Frequency 0 to 1000 Hz 0.0003 0.0002 0.003 0.0002 0.0001 CH1 1 kHz to 5 kHz** 0.0003 0.0004 0.003 0.0004 0.00001 CH1 0 to 999999 CPM Refer to equivalent frequency 0.01 CH1 0 to 999999 CPH Refer to equivalent frequency 0.01 CH1 Totalizing counter Maximum count 9999999 1 CH1 Trigger level Automatic and adjustable 0 to 20 V 0.1 Pressure 25 mbar to 1000 bar (0.35 psi to 15000 psi) Please refer to PM 620 pressure range table P1 P2 IDOS external module Please refer to IDOS UPM datasheet. P/N IO620-IDOS-USB+IO620-USB-PC required IDOS USB port Please refer to GE Sensing for compatible devices USB Source mode DC Voltage TC mode Please refer to Thermocouple specification table TC mode -10 to 100 mV 0.009 0.008 0.014 0.01 0 0.0005 0.001 CH1 0 to 200 mV 0.0045 0.004 0.007/0.0085** 0.005 0 0.0005 0.1 CH1 0 to 2000 mV 0.004 0.003 0.007/0.008** 0.005 0 0.0005 0.1 CH1 0 to 12 V 0.006 0.0035 0.01/0.018** 0.0035/0.004** 0 0.0005 0.001 CH1 Current 0 to 24 mA 0.01 0.004 0.015/0.016** 0.005/0.0065** 0 0.0005 0.001 CH1 CH2 0 to 24 mA(24 V looppower) 0.01 0.004 0.015/0.016** 0.005/0.0065** 0 0.0005 0.001 CH2 24 V loop power 24 V ±10% Resistance RTD Please refer to RTD specification table CH1 0 to 400 Ω (0.1mA) 0.024 0.0035 0.03 0.0075 0 0.001 0.01 CH1 0 to 400 Ω (0.5mA) 0.004 0.0025 0.008 0.003 0 0.001 0.01 CH1 400 to 2000 Ω (0.05mA) 0.048 0.0035 0.06 0.006 0 0.001 0.01 CH1 2k to 4 kΩ (0.05mA) 0.048 0.0035 0.06 0.0045 0 0.001 0.01 CH1 Maximum input current 0-400 Ω 5 mA, 400-2000 Ω 1mA, 2000-4000 Ω 0.5 mA Frequency 0 to 1000 Hz 0.0003 0.00023 0.003 0.00023 0.1 CH1 1kHz to 5 kHz** 0.0003 0.000074 0.003 0.000074 0.001 CH1 Output waveform Square, positive swing up to 12V (adjustable), negative swing -80mV (fixed) Sine and Triangular, adjustable amplitude and offset within the limits -2.5 to +12 V Square wave peak output 0 to 12 V +/-20mV (10 mA maximum) 0 to 99999 CPM Please refer to equivalent frequency 1 CH1 0 to 99999 CPH Please refer to equivalent frequency 1 CH1 Totalizing counter Maximum count 1000000. Rate 1 to 50,000 pulses/sec 1 CH1
Price: 1900 USD
Location: Vilnius
End Time: 2024-02-25T15:15:21.000Z
Shipping Cost: 43 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Calibrator Type: Process Calibrator
Ingress Protection: IP65 (Dust-tight, jets of water)
MPN: DPI620
Languages: English {Default}, Chinese, French, German, Italian, Portuguese,
Power supply: Lithium-Polymer battery (GE Part number : IO620-Battery);
Weight: 575 g (1.3 lb) – battery included.
Touch screen: YES
Brand: Druck
HART communicator: integrated
Country/Region of Manufacture: United Kingdom
Size (L: W: H): 183 x114 x 42 mm (7.2 x 4.5 x 1.7 in)
Display: 110 mm (4.3 in) diagonal; 480 x 272 pixels
Operating temperature: -10° to 50°C (14° to 122°F)