Description: Description ASG102 Digital Handheld Signal Generators 2 Channels Car Automotive Signal Generator Kit With CAN data function New Jinhan ASG102 Digital Handheld Signal Generators 2 Channels JHASG102 Automotive Signal Generator Kit With CAN data function 1.Interface introduction (1) Button description and main functions: F1: It is mainly used to switch between the first and fourth items. Or to switch the value of the selected item. F2: It is mainly used to switch between the 2nd and 5th items, or to switch the value of the selected item. F3: It is mainly used to switch between the 3rd and 6th items, or to switch the value of the selected item. OK: Determine the button for confirmation or save. : Up button for up selection or value increase. : Down button for down selection or value reduction. : Left button for moving one item (bit) to the left. : Right button to move one item (bit) to the right. CH : It is mainly used for switching between channel 1 and channel 2 configuration interfaces. MENU: Mainly used to return to the menu selection interface. 0-9: The number key changes the corresponding digit value to a numeric key value. : On/off. (2) Port description:(Figure 1-1) CH1: Channel 1 signal output. CH2: Channel 2 signal output. CAN: CAN data receiving end. Figure 1-1 (3) Instrument features: According to the automotive rules and actual needs of on-site diagnosis, the instrument summarizes and analyzes the characteristics of existing car signal generators: 1. The signal characteristics can be adjusted in real time: the signal can be adjusted at any time by adjust waveform, amplitude, frequency, missing teeth and other indicators. This feature greatly helps to determination of the fault in the vehicle maintenance process. 2. Two-channel waveform signal output can simultaneously output signals of different frequencies, amplitudes and waveforms within two bandwidths. 3. CAN bus function: It is mainly used to test whether the CAN bus of various models is in normal communication. The test rate is 10K, 20K, 33.3K, 50K, 62.5K, 83.3K, 125K, 250K, 500K, 1M. 4. Friendly HMI: the instrument adopts the most simple design idea, 320*240 large-screen liquid crystal display, the display interface logic is clear; the panel operation is clear, which is convenient for the operator to quickly carry out various operations. 5. the appearance is small and convenient, using over injection molding, good use of feel. The internal components are all imported, users can use it with confidence! (II) Main interface operation 1. After the instrument is turned on, enter the main operation interface (Figure 1-2). Press any button (except on/off key), the first item (channel 1) will be selected by default. 2. Then use the “ ” button to switch the selected item. 3. After selecting the item, press the OK button to enter the corresponding configuration interface. Figure 1-2 (III) Signal generator operation After booting into the main interface, press the button to select “Channel 1” or “Channel 2”, then press “OK” to enter the signal generator parameter setting interface. The signal generator operation interface is shown in Figure 1-3 Figure 1-4 Mainly configure output signal parameters such as frequency, amplitude, duty cycle, waveform, X, Y. 1.Waveform selection Press F1 to select the first item (“Waveform”), then use the “ ” or“ ” key or the direct numeric key to input the value (range 1-5, a total of 5 waveforms) to select the waveform to be output. The serial number can be seen on the display. Corresponding waveform. The waveform and corresponding serial number are as shown below: 2. Setting frequency Press the F2 key to select the “Frequency” item, use the “ ” or “ ”key to select a value of the frequency, and then add or subtract the value by “ ” or “ ” step or change the value by directly using the number keys. Note: The frequency value ranges from 1HZ to 8000HZ. 3. Set the amplitude Press the F3 key to select the “Amplitude” item, use the “ ” or “ ” key to select a certain value of the amplitude, and then use the “ ” or “ ” key to increase or decrease the value step by step of the bit or directly change the value by the number key. Note: The amplitude value ranges from 0V to 20V. 4.Set the duty cycle Press the F3 key to select the “Amplitude” item, use the “ ” or “ ” key to select a certain value of the amplitude, and then use the “ ” or “ ” key to increase or decrease the value step by step of the bit or directly change the value by the number key. 5. Set the X value X represents the number of sine waves or square waves. Press the F2 key to toggle the “X” item, use the “ ”or “ ” key to select a value of X, and then press the “ ” or “ ” key to step up or subtract the value or change the value directly by the number key. Note: The X value range is 1-199. 6. Set the Y value Y represents the number of straight lines. Press the F3 key to toggle the “Y” item, use the “ ” or “ ” key to step up or subtract the bit value or change the bit value directly by the number keys. Note: Y value range is 0-9. â Payment Terms 1.We accept PayPal only. 2.All major credit cards are accepted through secure payment processor PayPal. 3.Payment must be received within 7 business days of auction closing. 4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay. Shipping Terms - For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding. Return Terms 1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund. 2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA. 3. We reserve the right to refuse any returns for objective reasons. Custom Duties & Taxes 1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility. 2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping. Feedback 1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers. 2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap.
Price: 114.3 USD
Location: Shenzhen
End Time: 2024-09-20T08:38:52.000Z
Shipping Cost: 10 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Number of Channels: 2
Model: ASG102
Modified Item: No
Country/Region of Manufacture: China
Maximum Real-Time Sampling Rate: 89 GS/s
Oscilloscope Type: Digital Oscilloscope
Features: Handheld/ Portable
MPN: Does Not Apply
Brand: Unbranded
Maximum Bandwidth: 100 MHz