Description: About 1756-IA16The Allen-Bradley 1756-IA16 is a Sixteen (16) channel AC input module from the ControlLogix Programmable Automation Controller (PAC) platform. This module is used to interface discrete signaling devices such as switches, auxiliary contacts and similarly operating devices that are rated for 120VAC, nominal and voltage range of 74-132VAC with frequency of 47-63 Hz.The 1756-IA32 has Two (2) input groups with each input group having Eight (8) channels each. It is provided with individual channel status LED that activates to provide feedback regarding the state of each of the channel. Each of the input channel has a hardware delay time of 10 ms max + filter time for OFF to ON signal transition and 8 ms max + filter time for ON to OFF signal transitions. User selectable filter time for OFF to ON transition are 1 ms or 2 ms and 9 ms or 18 ms for ON to OFF transition. This module has a cyclic update time 200 µs-750 ms.This module draws Current from the backplane amounting to 100 mA @ 5.1 VDC and 2 mA @ 24VDC. It consumes a total backplane power of 0.58 Watts and maximum power dissipation of 5.8 W @ 60 °C (140 °F) with Thermal dissipation of 18.41 BTU/hr.The 1756-IA32 has a maximum OFF-state voltage of 20VAC and maximum OFF-state current of 2.5 mA. Similarly, the minimum ON-state current rating of 5 mA @ 74V AC and maximum ON-state current of 13 mA @ 132V AC. It is able to withstand a maximum inrush current of 250 mA peak.It has Sixteen (16) input channels, grouped into Two (2) groups of Eight (8) points per group. The 1756-IA16 module's operating voltage range is from 74 to 132 Volts AC at a frequency of 47 to 63 Hertz, while both the voltage category and input frequency are 120 Volts AC and 50/60 Hertz, respectively. This module has an input delay time of 10 milliseconds for OFF to ON transition the configured filter time (user-selectable at 1 or 2 milliseconds). For ON to OFF transition, hardware delay is 8 milliseconds maximum plus filter time ( user-selectable at 9 or 18 milliseconds). At 5.1 Volts DC, the current draw is 100 milliamps and there are 2 milliamps of current draw at 24 Volts DC. The total backplane power is 0.58 Watts and it dissipates 5.8 Watts of power at 60 degrees Celsius for and 18.41 BTU/hour of thermal energy. The maximum off-state voltage is 20 Volts and the current is 2.5 milliamps. The on-state current of the 1756-IA16, on the other hand, ranges from a minimum of 5 milliamps at 74 Volts AC to a maximum of 13 milliamps at 132 Volts AC. The maximum recorded inrush current is 250 milliamps peak, decaying to less than 37% in 22 milliseconds without activation.FAQ for 1756-IA16Can the 1756-IA16 accommodate an RTB?Yes, the 1756-IA16 can accommodate an RTB.How many diagnostic inputs does the 1756-IA16 have?The 1756-IA16 has 8 diagnostic inputs.What is the 1756-IA16's input frequency rating?The 1756-IA16's input frequency rating is 50 to 60 Hertz.Does the 1756-IA16 utilizes a Removable Terminal Block (RTB) for termination of signals?Yes. The 1756-IA16 is delivered with a Removable Terminal Block (RTB). Specific RTB for this module are 1756-TBNH 1756-TBSH.How many slot does the 1756-IA16 occupy in the ControlLogix chassis?The 1756-IA16 occupies a single slot of the chassis.Does the 1756-IA16 come with individual channel isolation?No. The 1756-IA16 does not have individual channel isolation however, it has group isolation with each group having Eight (8) inputs points each.Technical Description of 1756-IA16Allen Bradley ControlLogix Digital AC Input Module with 16 Inputs
Price: 209.97 USD
Location: dongguang,guangdong
End Time: 2024-11-02T07:34:33.000Z
Shipping Cost: 50 USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Brand: Allen-Bradley
Type: PLC Input Module
Analog/Digital: Digital
Model: Allen Bradley 1756-IA16
MPN: 1756-IA16
Controller Platform: ControlLogix
Country/Region of Manufacture: United States